What the Australian Standards are and why they matter for your next trade job

A spirit level, tape measure and unlabelled building plans on a plywood workbench in front of a timber-framed house extension.
In this article

"Built to Australian Standards" appears on quotes, websites and product packaging everywhere. But what are the Standards, who decides what's in them, and when do they actually have to be followed? For trades, the answers affect how you quote, how you build and what you can sign off on. For clients, they explain why a tradie might insist on doing something a particular way, even when a cheaper option looks fine.

What is an Australian Standard?

An Australian Standard is a published document that sets out specifications, procedures or guidelines so that products, services and systems are safe, consistent and reliable. They cover everything from how a shower should be waterproofed to how electrical installations are designed, tested and verified.

Some standards are joint Australian/New Zealand standards, which is why you'll see both "AS" and "AS/NZS" in front of the number. The number after the colon, such as AS 3740:2021, is the year of that edition.

Who writes them

Australian Standards are developed by Standards Australia, an independent, non-government, not-for-profit organisation. Standards are written by technical committees that bring together people from industry, government, consumer groups, academia and the trades, and drafts are released for public comment before publication. See the Standards Australia FAQs.

Standards Australia doesn't regulate, enforce or certify compliance with standards. That job belongs to governments, regulators, certifiers and, in some cases, independent certification bodies.

When are Australian Standards mandatory?

On their own, Australian Standards are voluntary. A law or regulation can make a standard mandatory by referring to it. A contract can also require the parties to follow a standard, even where the law doesn’t specifically require it.

For building and plumbing work, the most important way this happens is through the National Construction Code (NCC).

How the National Construction Code calls up standards

The NCC is produced by the Australian Building Codes Board (ABCB) and sets the minimum requirements for the design and construction of buildings, and for plumbing and drainage. It's given legal effect through each state and territory's building and plumbing laws, which can adopt different editions on different dates and apply local variations.

The NCC has three volumes:

  • Volume One covers mainly multi-residential, commercial, industrial and public buildings.
  • Volume Two covers houses and outbuildings, supported by the ABCB Housing Provisions.
  • Volume Three is the Plumbing Code of Australia.

The NCC calls up specific editions of standards in its Deemed-to-Satisfy provisions. If you use that path, follow the cited edition and the parts the NCC references. A Performance Solution is another way to show that the relevant NCC requirements are met. The NCC is free to read.

Electrical work is called up separately

Electrical installation work is mainly governed by state and territory electrical safety laws. Check the edition and amendments that apply where you work. For an example of how this is set out, see the NSW electrical standards and rules.

Standards that come up all the time

A handful of standards come up on everyday residential jobs. These examples explain what each standard covers. Check which edition and amendments apply to your job.

AS 3740 – Waterproofing of domestic wet areas

Covers materials, design and installation for waterproofing bathrooms, laundries and other domestic wet areas. The Housing Provisions also set out wet area requirements. If you use AS 3740 to show compliance, check which Housing Provisions still apply under your adopted NCC. The ABCB’s residential waterproofing guide explains how those provisions work together in NCC 2022.

AS/NZS 3000 – Electrical installations (the Wiring Rules)

Sets the requirements for designing, building and testing electrical installations. It's commonly called the Wiring Rules.

AS/NZS 3500 – Plumbing and drainage

A multi-part standard covering water services, sanitary plumbing and drainage, stormwater drainage and heated water services. The Plumbing Code of Australia (NCC Volume Three) references parts of the AS/NZS 3500 series.

AS 3959 – Construction of buildings in bushfire-prone areas

Sets construction requirements for buildings in designated bushfire-prone areas, based on the site's Bushfire Attack Level (BAL). It affects everything from windows and doors to roofing, vents and decking.

Others you'll often see

  • AS 1684 – Residential timber-framed construction, used for framing houses.
  • AS 2870 – Residential slabs and footings.
  • AS/NZS 5601 – Gas installations, used by gasfitters.

What it means in practice for trades

  • Know which edition applies. Check which NCC edition and transition rules apply to the project, then look up the edition of the standard it references. Ask your building surveyor or certifier if you’re unsure.
  • Follow manufacturers' instructions too. Product installation instructions and standards work together. Installing a product outside its instructions can affect both compliance and the warranty.
  • Keep records. Photos of waterproofing before tiling, test results and compliance certificates help if questions come up later.
  • Certificates matter. In many states, licensed electricians, plumbers and gasfitters must issue a compliance certificate for certain work. Check your regulator's rules.
  • Price compliant work properly. If a competitor's quote is much cheaper, it's worth explaining to the client what the standard requires and what your price includes.

Getting access to standards

Standards are generally paid documents. Standards Australia also runs a free Reader Room that lets Australian residents view selected standards for personal, non-commercial use, with limits on how often you can view them. Trade businesses that use standards regularly usually buy the ones they need or a subscription. Your industry association or regulator may also be able to point you to access options.

What it means for clients

  • "Built to Australian Standards" isn't a guarantee on its own. Ask which standards apply to your job and who will check the work, such as a building surveyor, certifier or plumbing inspector.
  • Some steps can't be skipped. If your tradie insists on a waterproofing step, a particular fixing or a test, it's often because the standard or code requires it.
  • Ask for paperwork. For electrical, plumbing and gas work, ask for the compliance certificate where one is required in your state.
  • Use licensed trades where the law requires it. Licensing and standards go hand in hand, because licensed trades are trained to work to the standards that apply to them.

The short version

Australian Standards are written by Standards Australia, are voluntary on their own, and can become mandatory when called up by law, including through an adopted NCC provision. A contract can also require compliance. For trades, working to the right standard is part of doing the job legally and well. For clients, it's a good reason to choose a qualified, licensed tradie and ask questions before work starts.

Trade businesses can claim their free listing on TradeBench to show customers what they do and where they’re based, and anyone can use it to find independent local trades and suppliers.

Explore these topics

Put it into practice

Explore businesses in categories connected to this topic.

Explore the directory

Recently published businesses in these categories. Browse profiles to find the right fit.

Find businesses near your project

Choose a trade or supplier and search by their base suburb or postcode.

Run a trade or supply business?

Give people a place to discover your business, explore your services and get in touch.

List your business

Keep reading

More from Article Hub to explore next.

Browse all articles